Signal amplification by combining two advanced immunohistochemical techniques

Published: 26 June 2009
Abstract Views: 417
PDF: 573
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

The immunohistochemical techniques known as EnVision™+ System (EVS) and Mirror Image Complementary Antibody (MICA) were recently introduced into laboratory practice because of their high sensitivity. In this paper these techniques were compared and their sequences combined to obtain a new method possibly more sensitive than the original ones. The immunohistochemical staining employing the avidin-biotin complex (ABC), largely used as routine, was adopted as a term of comparison. Samples from the small and large intestine of pigs and sheep were fixed in Bouin and embedded in Paraplast. The primary antibodies utilized were directed against the neuronal nitric oxide synthase (nNOS), vasoactive intestinal polypeptide (VIP) and chromogranin A (Cr A). Targets of these antibodies were nerve structures of the intestinal wall, as well as endocrine cells scattered in the mucosa of the bowel, defined neuroendocrine cells or paraneurons. The EVS method appeared as slightly superior to the MICA method regarding sensitivity of detection. The EVS/MICA (combined) method resulted four/eight times more effective than the original techniques regarding sensitivity of detection and staining intensity, both at low and high dilutions of the primary antibodies. Of these latter, immunopositive structures were still clearly identifiable, at a dilution of 1:256,000. Such efficiency could be explained by the high number of revealing molecules of peroxidase contained in the new sequence. The application of the combined method is recommended when a small quantity of tissue antigens needs to be detected immunohistochemically.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

How to Cite

Russo, D., Ambrosino, A., Vittoria, A., & Cecio, A. (2009). Signal amplification by combining two advanced immunohistochemical techniques. European Journal of Histochemistry, 47(4), 379–384. https://doi.org/10.4081/850

Publication Facts

Metric
This article
Other articles
Peer reviewers 
0
2.4

Reviewer profiles  N/A

Author statements

Author statements
This article
Other articles
Data availability 
N/A
16%
External funding 
N/A
32%
Competing interests 
N/A
11%
Metric
This journal
Other journals
Articles accepted 
57%
33%
Days to publication 
0
145

Indexed in

Editor & editorial board
profiles
Academic society 
N/A